Agricultural Automation

Engineering is concerned with the development, improvement, and implementation of inte grated systems of people, money, knowledge, information, equipment, energy, materials, analysis and synthesis, as well as the mathematical, physical and social sciences together with the principles and methods of engineering design to specify, predict, and evaluate the results to be obtained from such systems or processes.

Concerned with the development, improvement, and implementation of integrated system of people, money, knowledge, information, equipment, energy, materials, analysis and syn thesis, as well as the mathematical, physical and social sciences together with the principle and methods of engineering design to specify, predict, and evaluate the results to be obtained from such systems or processes.

Raising a heavy fur muff that covered the whole of her lower arm towards the viewer gregor then turned to look out

William Jomurray Envato Author

System Benefits

Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam. Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam. Lorem ipsum dolor sit amet, consectetur adipisicing elit.

  • Pitifully thin compared with the size of the rest of him.
  • Raising a heavy muff that covered the whole. muff that covered the whole of her lower arm consectetur.
  • Muff that covered the whole of her lower arm consectetur adipisicing elit

3,800.00 THB

(4 customer reviews)
Brand: SCHNEIDER ELECTRIC
Product Number: 2020883
MPN: LE1M35M722
Rated control supply voltage Us at AC 60HZ 220...220V
Voltage type for actuating AC
Number of command positions 1
Rail mounting possible no
Ambient temperature, upper operating limit 40°C
Number of auxiliary contacts as normally open contact 0
With transformer no
Temperature compensated overload protection yes
Overload release current setting 12...16A
Rated operation current at AC-3, 400 V 16A
Rated control supply voltage Us at AC 50HZ 220...220V
Rated operation power at AC-3, 400 V 7.5kW
Rated operation current Ie 16A
Number of auxiliary contacts as normally closed contact 0
Type of electrical connection for auxiliary- and control current circuit Screw connection
With short-circuit release no
Rated operation power at AC-3, 230 V, 3-phase 3.7kW
Type of electrical connection of main circuit Screw connection
Release class CLASS 10 A
Type of motor starter Direct online starter (DOL)